| * Energy saving Return On Investment (ROI) improves as energy prices rise |
|
Solutions for energy efficiency
* Power metering & Monitoring
What you can’t measure, you can’t control |
|
Description:
This advanced power metering & monitoring system consists of powerful, accurate power measurement devices connected to power monitoring and control software using the latest communications technologies
Features & benefits:
> Understand usage patterns to detect abnormal consumption that may be caused by faulty equipment
> Save money following recommendations regarding subscription, peak demand, period rate, and penalties
> Optimize the use of existing capacity and avoid over-design thanks to load studies and circuit optimization
> Avoid penalties with automated load shedding, scheduling, peak shaving or capacitor
bank control.
> Allocate energy sub billing energy usage allocating costs according to cost centre, production unit, shift, etc
Web Energy - Remote energy monitoring services
Differentiation factors:
> WAGES (water, air, gas, electricity, steam) monitoring
> Provides access to the Schneider-Electric hosted application (Servers) at anytime from anywhere.
> Delivers data and notifications in case of abnormal trends.
> Provides tools for analysis of energy usage including group economy and benchmarking.
> Includes scheduled e-mail reporting
|
| * Lighting control |
|
Description:
To reduce lighting energy consumption and improve user comfort in the large entrance halls, long corridors, large conference rooms. Up to 65% with occupancy sensors, up to
40% via daylight dimming, up to 13% via lumen control and up to 35% with time scheduled
Features & benefits:
> Up to 20% energy saving by automatically extinguishing lighting when it is not necessary.
> Automation ensures major energy saving, increased comfort and enhanced safety.
|
* Power Factor Correction
Do you pay penality for low power factor ? Why not to get paid? |

|
Description: Power Factor correction bank solutions modify & control the reactive power to avoid utility penalties. Besides, the installation of a capacitor bank has a fast pay-back thanks to the saving on your electrical invoice |
|
|
| |
Features & benefits:
> Reduce your operating expenses up to 10% penalties or bonus are applied
> Increase the life-time and reliability of electrical devices
> Reduce your capital expenses up to 30% by optimizing the size of your installation & Increasing the power availability
> Reduce the size of transformers, cables and switchgear equipments
> Reduce the voltage drops & reduce the level of harmonics
> Use environment friendly solutions contribute to the reduction of CO2 emission thanks to lower energy consumption up to 30%
|
| * Harmonic filtering |
|
Description:
Certain equipment such as drives, inverters, UPS,
arc furnaces, transformers, filters and discharge lamps generate harmonics. The harmonics strain the network. Voltage distortion overload cables, cause failures of relays and circuit breakers and disturb many types of equipment such as computers, telephones etc….Implemented by experienced specialists, the harmonic filtering solutions (active & passive filters) eliminate most of the power quality problems
Features & benefits:
> Optimize the sizing and the life duration of your electrical equipment by reducing to the minimum the warming up of electrical equipment and increasing the service life of equipment, cables & transformers
> Improve the continuity of your production processes eliminate the production machinery stopping risk
> Increase the availability of your electrical utilities in factories and buildings eliminate the strongly negative impacts of harmonics on all electronic devices: computers, telephones etc.
> Improve your compliance with electrical utilities requirements anticipate the increasingly severe expectations and standards: implement durable development solutions
|
* Variable speed drives
Are you running motors at full speed even when lower levels of flow are required? |
|
Description:
> 72 % of consumed electricity is used to turn on motors. 63 % for fans & Pumps motors. Inefficient throttling or control methods are used and motors energy consumptions remain high. AC drives allow you to reduce energy consumption by 50% on fans compared to conventional solutions and 20% to 30% on pumps according to their characteristics.
> Fans: at 80% of nominal flow, the energy consumption is 95% of nominal power with conventional installations instead of 50% with
AC drives.
> Pumps: even thought flow variation is not needed, most of the applications are AC drives save 20% of energy compared to conventional solutions.
> Using ECO8 software, you can easily estimate the energy saving according to your pump or fan applications and duty cycle.
Features & benefits: > High performance variable torque applications:
> Fan: safety with forced start (fault inhibition, selection of the running direction and reference speed).
> Multi pump: with the programmable multi pump card, Altivar 61 brings you flexibility, usability and adaptability in management of multiple pumps.
> Pumps: essential functions to protect your installation under load, including detection of overload and fluid absence.
> IP54 version and "Simply Start" menu
HVAC control
70 to of HVAC applications (Air handling units and cooling towers) are fan applications. Compared to conventional installations, such as motor starter and flow regulation by an outlet valve, AC drives allow you to save up to 50% on energy consumption. On top of that, the Altivar 21 allows you to optimize
the motor control according to the load (air density). This result an additional percentages of energy savings.
Differentiation factors:
> Open to the main building communication networks: LonWorks, and BACnet.
> All essential functions for variable torque pumps and fans applications: PI regulator, automatic restart, recovery with the flight, skip frequencies, belt breakage detection, overload detection & under load detection
> "Harmonic less" and "plug & drive"
|
|
| |